About 167,000 results
Open links in new tab
  1. Introduction to Pitot-Static Systems in Gliders - Physics Forums

    Aug 18, 2024 · A pitot-static tube has both the pitot port and the static port. The pressure difference between the two is a basis for airspeed measurements. In the illustration, we see a …

  2. Reverse Pitot Flow: Pressure Differential? • Physics Forums

    May 7, 2007 · Reversing the flow direction in a pitot measuring system may still result in a pressure differential between the pitot and static tubes. It is suggested that a small area of low …

  3. Bernoulli Principle For Pitot Tubes - Physics Forums

    Sep 28, 2020 · The discussion centers on applying the Bernoulli Principle to two pitot tubes measuring static and dynamic pressure, revealing a contradiction in the derived equations. …

  4. Pitot Tube Experiment: Measuring Pressure & Velocity

    Jan 6, 2011 · The discussion revolves around an experiment using a pitot tube to measure pressure and derive velocity profiles for calculating mass flow rate. The experiment setup …

  5. Measuring velocity in a pitot-static tube and manometer

    Apr 4, 2012 · A Pitot-static probe connected to a water manometer measures air velocity based on the deflection of fluid levels. The calculated air velocity, using the formula derived from …

  6. How to be sure your pitot-static tube is aligned correctly with the ...

    Sep 19, 2012 · To ensure proper alignment of a pitot-static tube in a wind tunnel, it should be oriented so that the static ports show the lowest pressure reading while the stagnation …

  7. Dynamic pressure and pitot tube - Physics Forums

    Sep 15, 2015 · A pitot tube measures both static and dynamic pressure when oriented correctly in the airflow. If reversed, it primarily measures static pressure, potentially influenced by vortices …

  8. Difference between a subsonic Pitot tube and supersonic one

    May 13, 2015 · Subsonic Pitot tubes measure stagnation pressure accurately, while supersonic Pitot tubes face challenges due to shock waves and non-isentropic flow, leading to potential …

  9. Selecting the Right Radius for Pitot Static Tube Measurement in ...

    Nov 8, 2008 · Selecting the radius of a pitot static tube for airflow testing in a circular tube involves understanding both the tube's construction diameter and the measurement radius from the …

  10. Calculating Residual Pressure for Fixed Orifice Flow

    Dec 26, 2009 · See the pitot tube. IMO this sentence should be corrected to "Total pressure = pressure that is measured when water is at rest. Under no-flow conditions, Static Pressure = …